开间为9m,共同作用支撑数为1(风荷载将在这些屋面支撑间平均分配) 。
结构简图如下所示:

屋面支撑采用柔性支撑体系。
截面布置如下:
|
杆件号 |
截面 |
材料 |
|
1 |
H-900*300*10*16 |
Q235 |
|
2 |
H-900*300*10*16 |
Q235 |
|
3 |
H-900*300*10*16 |
Q235 |
|
4 |
H-900*300*10*16 |
Q235 |
|
5 |
H-900*300*10*16 |
Q235 |
|
6 |
H-900*300*10*16 |
Q235 |
|
7 |
H-900*300*10*16 |
Q235 |
|
8 |
H-900*300*10*16 |
Q235 |
|
9 |
H-900*300*10*16 |
Q235 |
|
10 |
H-900*300*10*16 |
Q235 |
|
11 |
H-900*300*10*16 |
Q235 |
|
12 |
H-900*300*10*16 |
Q235 |
|
13 |
PIPE-146*4.5 |
Q235 |
|
14 |
PIPE-146*4.5 |
Q235 |
|
15 |
PIPE-146*4.5 |
Q235 |
|
16 |
PIPE-146*4.5 |
Q235 |
|
17 |
PIPE-146*4.5 |
Q235 |
|
18 |
PIPE-146*4.5 |
Q235 |
|
19 |
PIPE-146*4.5 |
Q235 |
|
20 |
L-100*63*6 |
Q235 |
|
21 |
L-100*63*6 |
Q235 |
|
22 |
L-100*63*6 |
Q235 |
|
23 |
L-100*63*6 |
Q235 |
|
24 |
L-100*63*6 |
Q235 |
|
25 |
L-100*63*6 |
Q235 |
|
26 |
L-100*63*6 |
Q235 |
|
27 |
L-100*63*6 |
Q235 |
|
28 |
L-100*63*6 |
Q235 |
|
29 |
L-100*63*6 |
Q235 |
|
30 |
L-100*63*6 |
Q235 |
|
31 |
L-100*63*6 |
Q235 |
风载:分项系数为1.4,荷载取值见结构简图。
风载导算参数见下:
基本风压: 0.4kN/m 2 ;
体型系数1,风压高度变化系数1.14;
风振系数为1;风压综合调整系数1.05;
分担风荷载的高度为 5m。
结构风载下轴力设计值简图如下所示:

最不利系杆 13 采用截面 PIPE-146*4.5-Q235
截面面积:A=20.004cm 2
平面内计算长度:Lx=9m
平面外计算长度:Ly=9m
平面内长细比:λx=9/5.005×100=179.809
平面外长细比:λy=9/5.005×100=179.809
最大长细比:λmax=179.809
<220, 合格
稳定系数:φ=0.2435
稳定验算:σ=50.08/20.004/0.2435×10=102.816N/mm 2 <215MPa, 合格
最不利斜腹杆 21 采用截面 L-100*63*6-Q235
截面面积:A=9.62cm 2
强度验算:单角钢强度折减系数:0.85
单角钢修正强度取值:215×0.85=182.75N/mm 2
σ=47.438/9.62×10=49.312N/mm 2 <182.75MPa, 合格
平面内计算长度(m) lx = 5.148
平面外计算长度(m) ly = 10.296
回转半径 imin= 0.13800E-01
iy = 0.3210E-01
长细比校核 λx = 373.040<[λ]= 400
Λy = 320.75<[λ]= 400
验算满足。
结构静力组合设计应力简图如下所示: